- Height (mm)
- 481
- Width (mm.)
- 170
- Depth (mm)
- 82
- Weight
- 4.2 Kg.
- Supply voltage
- 24 264÷83 Vac with power reduction under 108 Vac
- Temperature of use
- -15°C to 70°C, with linear power reduction above 45°C
- Maximum output current
- 100 A
- Charging voltage in absorption
- 28.2 Vdc OL - 28.4 Vdc Li-Ion28.8 Vdc SL/GEL/AGM - 29.4 Vdc Optima® - 29.4 Vdc Optima
- Float charging voltage
- 26.8 Vdc OL - 27.0 Vdc Li-Ion - 27.2 Vdc AGM 27.6 Vdc SL/GEL/Optima®
- Number of outputs
- 3
- Frequency
- 45 ÷ 66 Hz
- Efficiency
- ≥ 92%
- Max absorption (230/240 Vac)
- 12.5 A
- Cooling
- Forced, with variable fan speed
- -30.26%
The new SBC NRG+ battery chargers are more compact and equipped with connectors that make connection quick and easy. Thanks to their high efficiency (up to 92%), they offer significant reductions in consumption, lower heat generation, and greater system reliability.
Purchased together
Alternative products
Product Details
Description
Quick has been designing and manufacturing battery chargers for around 25 years, and has always proven to be one step ahead of market standards.
With the SBC series, NRG once again confirms its success by choosing the most cutting-edge technological solutions and dedicating particular attention to improving energy efficiency.
The benefits of the new project translate into: reduced consumption, lower heat development, reduced acoustic noise, less invasive derating and greater system reliability.
The new SBC NRG PLUS series also features the reliability and advantages already tested with the previous ADV PLUS series and all the levels of protection designed to guarantee maximum battery protection , the ability to deliver full power even in extreme conditions and the use of high quality components and materials .
Advantages:
- IUoU three-stage charging characteristic.
- High efficiency.
- Multiple outputs to charge multiple battery packs.
- Differentiated charging for liquid electrolyte batteries (open or sealed), gel, AGM, Optima®
- Output fuse built into the charger.
- Ability to deliver full power at low AC mains voltage.
- Low residual ripple on the output.
- Universal AC mains input
- Power factor (cos ϕ) equal to 1.
- Variable speed cooling fan.
- Compatibility with generators.
- Short circuit, overload, output overvoltage and overheat protections.
- Operation over a wide ambient temperature range.